Reliable surge protection and international certification in PV and DC power systems --- Raycap SPD

Raycap's SPD (surge protection device) is available in Type 1, Type 2, Type 1+2 and DC-only SPD according to international standards (IEC/UL) , and its main product lineup is as follows.

Raycap SPD specifications and types

  • Type 1 SPD : Mainly installed at the main power inlet (main board) of a building, to protect against lightning.

  • Type 2 SPD : Installed in indoor distribution systems such as distribution panels, to protect against lightning and switching surges.

  • Type 1+2 SPD : Integrates Type 1 and 2 functions for various environmental protection applications.

  • DC SPD : DC-only devices for solar power, batteries, EV charging, BESS, etc. Compliant with IEC 61643-41, UL 1449, etc.

Raycap's flagship product lineup

  • Strikesorb series (30, 40, 35, 80) : High performance, Type 1/2 compatible, for mounting on industrial main boards and distribution panels.

  • ProTec series

  • ProTec T1SF, T1S: Type 1+2, industrial SPD with built-in fuse and no leakage current.

  • ProTec T1 LH: Compact size Type 1.

  • ProTec T1 PV 5Y and PV Box: Type 1 SPD for solar inverters and connection boxes.

  • ProTec T2 DC-41: For DC DIN rail, specialized for DC equipment such as EV charging and BESS.

  • RayDin, Rayvoss : Customized surge protection solutions for industrial system integration.

  • Safetec T1, T2: Customized surge protection solutions for industrial system integration, with specialized products with strong TOV resistance.

  • PCB Socket T1 PV : Direct PCB attachment, for solar power generation and electronic equipment.

  • Signal Line SPD : SPD for signal and data line protection.

Key Features

  • Supports various voltage ranges (AC/DC 250V~1500V), impulse currents (up to 50kA or more), installation for communication/control signals, and remote contacts (status monitoring).

  • UL, IEC international standard certified product line, widely applicable to industrial, building, and renewable energy facilities.

The Raycap product line is optimized for not only the energy sector but also industrial, building, and digital power grid applications, and is available in a variety of specifications.

IEC 61643-31, 32, and 41 are international standards for surge protective devices (SPDs) in photovoltaic (PV) installations and DC systems, each defining specific requirements, tests, and application guides .

IEC 61643-31

  • Scope : Specifies the requirements and test methods for surge protection devices on the DC side (up to 1,500 V DC) of solar power generation facilities.

Technical details :

  • Protects the DC side of the PV system from lightning or other transient overvoltages (surges).

  • Specify performance characteristics (surge immunity, protection level), safety, and standard tests (impulse discharge current, maximum continuous operating voltage, etc.).

  • Applies only to permanently installed (fixed) SPDs, installed on the DC input side of solar power generators and inverters.

  • Includes production, installation, maintenance and acceptance testing.

  • Related tests : IEC 60060, IEC 60529 (IP Code), IEC 62475 (high current test), IEC 61643-11 (except dual port for DC).

IEC 61643-32

  • Scope of application : Provides principles for selection and application of SPDs connected to photovoltaic (PV) installations .

Technical details :

  • When installing SPD on the DC and AC side, selection, method, application location, cable cross-section area, and grounding method are specified.

  • Calculation of SPD test ratings, surge current values, and bonding conductor cross-sections according to various PV system structures.

  • Differences in SPD application principles depending on the presence or absence of an external lightning protection (LPS) system and the installation distance (safety distance).

  • Provides location-specific and environment-specific installation guidelines for effective lightning/switching surge protection.

  • Test/Installation Guide : Separate installation principles for each PV source/array, inverter, and connector, and application of SPD recommendations for each system and test grade.

IEC 61643-41

  • Scope : Defines performance standards and test methods for surge protection devices used in renewable and DC power sources, such as energy storage systems (ESS) and DC microgrids.

Technical details :

  • Specifies component-specific performance, test parameters, failure modes, and reliability criteria for DC high-voltage (typically 1,500 V or less) loads.

  • Confirming the required characteristics and safety of SPDs in ESS/BESS, DC battery/charging infrastructure, and new renewable microgrid systems.

  • Details : Based on IEC-61643-31, including extended test items and requirements specific to DC energy storage environments.